Harmonic solution and power quality


Show:
Sort By:

DV/DT filter, Rated Current413A ,for 200KW Motor

Dv/dt filters DescriptionThe SIKES DV/DT  filters decreases the insulation stress of motors by lowering the dU/dt value of the variable speed drive output voltage. It can be utilized with cable lengths up to 100 to 300 m depending on the model.Moreover, the units are intended for maximum switch..

DV/DT filter, Rated Current419A ,for 220KW Motor

Dv/dt filters DescriptionThe SIKES DV/DT  filters decreases the insulation stress of motors by lowering the dU/dt value of the variable speed drive output voltage. It can be utilized with cable lengths up to 100 to 300 m depending on the model.Moreover, the units are intended for maximum switch..

DV/DT filter, Rated Current484A ,for 250KW Motor

Dv/dt filters DescriptionThe SIKES DV/DT  filters decreases the insulation stress of motors by lowering the dU/dt value of the variable speed drive output voltage. It can be utilized with cable lengths up to 100 to 300 m depending on the model.Moreover, the units are intended for maximum switch..

DV/DT filter, Rated Current63A ,for 30KW Motor

Dv/dt filters DescriptionThe SIKES DV/DT  filters decreases the insulation stress of motors by lowering the dU/dt value of the variable speed drive output voltage. It can be utilized with cable lengths up to 100 to 300 m depending on the model.Moreover, the units are intended for maximum switch..

DV/DT filter, Rated Current721A ,for 400KW Motor

Dv/dt filters DescriptionThe SIKES DV/DT  filters decreases the insulation stress of motors by lowering the dU/dt value of the variable speed drive output voltage. It can be utilized with cable lengths up to 100 to 300 m depending on the model.Moreover, the units are intended for maximum switch..

DV/DT filter, Rated Current76A ,for 37KW Motor

Dv/dt filters DescriptionThe SIKES DV/DT  filters decreases the insulation stress of motors by lowering the dU/dt value of the variable speed drive output voltage. It can be utilized with cable lengths up to 100 to 300 m depending on the model.Moreover, the units are intended for maximum switch..

DV/DT filter, Rated Current807A ,for 450KW Motor

Dv/dt filters DescriptionThe SIKES DV/DT  filters decreases the insulation stress of motors by lowering the dU/dt value of the variable speed drive output voltage. It can be utilized with cable lengths up to 100 to 300 m depending on the model.Moreover, the units are intended for maximum switch..

DV/DT filter, Rated Current91A ,for 45KW Motor

Dv/dt filters DescriptionThe SIKES DV/DT  filters decreases the insulation stress of motors by lowering the dU/dt value of the variable speed drive output voltage. It can be utilized with cable lengths up to 100 to 300 m depending on the model.Moreover, the units are intended for maximum switch..

DV/DT filter, Rated Current999A ,for 560KW Motor

Dv/dt filters DescriptionThe SIKES DV/DT  filters decreases the insulation stress of motors by lowering the dU/dt value of the variable speed drive output voltage. It can be utilized with cable lengths up to 100 to 300 m depending on the model.Moreover, the units are intended for maximum switch..

Sine wave filter plus EMC, with DC link connection Rated Current 10A

Sine wave plus EMC filter  Description :This is a Sine Wave and EMC Output Filter for Motor Drives with a DC Link Access. It will eliminate the disturbance between phase and ground. Normal sine wave filter only works between phases. With improved sine wave filter you can use unshielded motor ca..