SIKES

Show:
Sort By:

Load Reactor for high speed motor, 400-1200Hz, 400A/690V

Description of Load Reactor:SKS-OCL series Load Reactors are placed in series with electrical equipment to introduce a specific controlled impedance to the AC circuit. This series are applied at AC drive output side to suppress inrush voltage, reducing inrush and peak current, improving real po..

Medium frequency adjustable load reactor 800A/1000V, multiple sets of inductors for testing

Load reactor is designed to test frequency inverter.Features of Three-phase load reactor:The windings adopt foil winding structure, which has small DC resistance, Strong at short circuit withstand capability and short time overload capability;The use of composite insulation materials with an insulat..

Passive Harmonic Filter , THDi<10%, Rated Current 100A, Open frame

Description of Passive Harmonic Filter:Sikes passive harmonic filter is designed for almost any kind of electronic applications with six pulse front end rectifiers . The filter can efficiently reduce the harmonic current distortion to required level.Typical application:non-linear three-phase p..

Passive Harmonic Filter , THDi<10%, Rated Current 11A, New design

Sikes passive harmonic filter is designed for almost any kind of electronic applications with six pulse front end rectifiers . The filter can efficiently reduce the harmonic current distortion to required level.Typical application:non-linear three-phase power supplies where potential risk is..

Passive Harmonic Filter , THDi<10%, Rated Current 129A, Open frame

Description of Passive Harmonic Filter:Sikes passive harmonic filter is designed for almost any kind of electronic applications with six pulse front end rectifiers . The filter can efficiently reduce the harmonic current distortion to required level.Typical application:non-linear three-phase p..

Passive Harmonic Filter , THDi<10%, Rated Current 129A, Open frame

Description of Passive Harmonic Filter:Sikes passive harmonic filter is designed for almost any kind of electronic applications with six pulse front end rectifiers . The filter can efficiently reduce the harmonic current distortion to required level.Typical application:non-linear three-phase p..

Passive Harmonic Filter , THDi<10%, Rated Current 14A, New design

Sikes passive harmonic filter is designed for almost any kind of electronic applications with six pulse front end rectifiers . The filter can efficiently reduce the harmonic current distortion to required level.Typical application:non-linear three-phase power supplies where potential risk is high du..

Passive Harmonic Filter , THDi<10%, Rated Current 154A, Open frame

Description of Passive Harmonic Filter:Sikes passive harmonic filter is designed for almost any kind of electronic applications with six pulse front end rectifiers . The filter can efficiently reduce the harmonic current distortion to required level.Typical application:non-linear three-phase p..

Passive Harmonic Filter , THDi<10%, Rated Current 16A, Open frame

Description of Passive Harmonic Filter:Sikes passive harmonic filter is designed for almost any kind of electronic applications with six pulse front end rectifiers . The filter can efficiently reduce the harmonic current distortion to required level.Typical application:non-linear three-phase p..

Passive Harmonic Filter , THDi<10%, Rated Current 188A, Open frame

Description of Passive Harmonic Filter:Sikes passive harmonic filter is designed for almost any kind of electronic applications with six pulse front end rectifiers . The filter can efficiently reduce the harmonic current distortion to required level.Typical application:non-linear three-phase p..